ERS Software for ergoline Rehabilitation System

Systematically developing the performance of the cardiovascular system is one of the major goals of cardiological rehabilitation.

ergoline has developed ERS, its superior, intuitively operated system in close cooperation with physicians and therapists. This system is flexible enough to easily adapt to the most varied requirements. Cardiovascular training with simultaneous monitoring of the ECG can be conducted with up to 16 patients at once. The ERS PC software will control the entire training session for each patient on the basis of the predefined protocols, it simultaneously documents all relevant data (e.g. ECG, heart rate, training data) and frees the therapist from routine tasks so that patients can be more intensively supervised.

Order

Systematically developing the performance of the cardiovascular system is one of the major goals of cardiac rehabilitation. Ergometer training on the basis of standardized protocols has more and more become the gold standard in rehabilitation. In close cooperation with physicians and physiotherapists, ergoline developed its new ERS system concept, an intuitive, sophisticated tool which is flexible enough to easily adapt to the most varied requirements.
The quality guidelines for cardiac rehabilitation today make high demands on the systems used. The acquisition and storage of full-disclosure data including ECG, heart rate and blood pressure for the duration of the entire test is of particular importance. From chipcard-assisted creation of individual training protocols and reliable patient tracking to the automatic control of the connected ergometers and treadmills as well as the comprehensive monitoring of the training sessions, there is no need to accept compromise. The full documentation of all data - even over long periods of time - is a must for the meaningful evaluation of the training outcome.
On the basis of the full-disclosure ECG and other training data displayed and stored in real time of up to 16 patients, the physiotherapist is able to quickly assess the patient status at any time during the training. The alarms whose criteria can be separately defined for each individual patient are readily identified on the display.
Even while the training is in progress, a patient's training and alarm parameters can be easily modified and adapted. In addition to manual modifications you can toggle between heart-rate-targeted and constant-load protocols at any time. It is also possible to stop the test for an individual patient whenever necessary.
With a host of options for defining warm-up, exercise and recovery phases, a patient's personal training protocol is easy to configure.
You can specify a load for constant-load tests, or you specify a target pulse rate and the ergometer will adapt the load to keep the pulse at a constant rate.
Interval training can be selected to meet special training requirements. Interval protocols specify individual training units to the second - the graphic assists in defining the protocol phases. You can click on a particular patient's current training data at any time to view them at a larger scale. The ECG data stored up to this point can be reviewed on screen.
Comparing data directly with previous training sessions provides important information for the assessment of the patient's current performance. While reviewing a patient's individual data, you never lose sight of the other ECGs and you can switch to another patient at any time.
All of a patient's single training sessions can be reviewed at any workstation in the network. The full-disclosure ECG data as well as all other trainingrelated information are available for analysis. Events earkmarked during the training can be accessed directly. Previously acquired diurnal profiles are only a mouseclick away. On the basis of the diagram illustrating all training units that a particular patient has completed, you can easily assess the therapy outcome. In addition to the load levels reached, the graphs also provide a concise, clear presentation of the heart rate and blood pressure trends (warm-up, training, recovery). Tabular data preferred? View the training parameters in tabular format and export them for further processing.

Technical data

Ergometer for cardiac rehabilitation

 

Brake system

microprocessor controlled eddy current brake

Load / accuracy

6 - 999 Watt, speed independent / according to DIN VDE 0750-238

Speed range

30 - 130 rpm

Handlebar adjustment

- angle: 360°         - angle: 360° / height: 90-126 cm

Saddle height adjustment

– mechanical, continuous

– motor-driven, continuous

Patient weight

150 kg (max.)

Control unit

 

Graphic display / patient display

load, rpm, time, blood pressure, heart rate, ECG (LCD) / rpm (LED)

Keyboard

membrane keyboard

ECG amplifier

single-channel ECG amplifier (3 individual leadwires / disposable electrodes)

Chipcard reader

Options

 

Electrode application system (3 vacuum intensities)

Automatic blood pressure measurement

Oxygen saturation measurement

Miscellaneous

 

Interface

digital (RS-232) for ERS system

Dimensions, max. (L x W x H) / weight

approx. 90 cm x 46 cm x 133 cm / 61-69 kg

Power

90-265 V / 50-60 Hz / 60 VA max.

ERS software

 

Ergometer control (incl. ECG, chipcard)

16 ergometers max.

Treadmill control (incl. ECG, chipcard)

Patient and analysis database

Patient diagnosis / anamnesis

integrated diagnosis worksheet

Training types (individual / group training)

constant pulse / constant load / interval / user-programmed protocols (incl. warm-up and recovery phases)

ECG storage

continuous for all patients and all analyses

Documentation

storage of all training data / numerous display and printout formats

Network-compatibility / data export / archive

 

Standard              - Option

Please order the detailed ERS system description.

ERS Software

OptionsDescriptionID
Сетевая версия программы ERS
ERS network version
  •     Access to all evaluations in the PC network
erg161.347
Управление бегущей дорожкой
 Treadmill control
  •     Connection module for treadmill control by ERS
  •     integrated 1-channel ECG amplifier
  •     3 ECG leadwires for disposable electrodes
  •     Integrated chip card reader
erg161.358
Управление бегущей дорожкой
ERS archiving
  •     Software module for archiving test evaluations
erg161.350
Управление бегущей дорожкой
GDT connection
  •     Software module for ERS connection to the hospital computer system
  •     Import of patient data
  •     Export of results
erg161.349

Accessories

Устройство считывания карт памятиChip card readererg705.225
Карты памятиChip cardserg705226

 

 