Duo Photometer DP 200

The reliable partner in the gynecological practice

Duo Photometer – Precise, safe, simple The Duo Photometer determines the following parameters Hemoglobin, Hematocrit, Erythrocytes. The Duo Photometer is characterized by an extraordinary high accuracy of the test results. It is assured primarily by the measuring principle, which is based upon the reliable wet-chemical photometric method. Continuous inspections by independent reference institutions (INSTAND and DGKL) ensure the user a constant high quality of the device and reagent. The reagent is ready for use and supplied in round cuvettes. Only the sample needs to be added. The carrying case contains all required accessories and guarantees the user’s mobility at any time. The red blood pigment, Hemoglobin (HB) is a protein with iron content which is responsible for the transportation of oxygen in the bloodstream. It serves the purpose to monitor risk groups for iron deficiency, such as pregnant women, toddlers, blood donors, hemodialysis patients, and sportswomen. The number of red blood cells is determined by measuring the Erythrocytes (ERY). Low values are determined as soon as anemia as are existent. They cause a decline of physical fitness. The determination of Hematocrit (HCT) indicates the percentage of the red blood cells. It serves both as a control of success of the endurance training and as a detection of performance-reducing and health threatening blood swellings, which occur if there is too much stress and the hydration, is insufficient. Besides monitoring risk groups, the most important field of application are emergency diagnostics (loss of blood) and monitoring the HB value during surgery.

Download

Chapbooks
Order

Duo Photometer:

 

  • Size: 19.5 x 10.0 x 4.5 cm
  • Weight: 0.4 kg
  • Wavelength: 546 nm
  • Saves all measured values
  • RS 232C interface – Mains or battery (9V)-operated
  • Photometric inaccuracy < 0,5 % at E = 1.000

 

 

 

 

 

Ready-to-use tests

  • HB 142 Haemoglobin
  • HB 342 Haemoglobin, 
  • SLS-method immediate measurement, no waiting period, free of cyanide
  • ERY 142 Erythrocytes
  • HCT 142 Haematocrit
  • Sample material
  • 10 μL capillary, venous blood

Report templates

 

  • Under the guidelines of the German medical chambera control and a recorded result are required at least once a week for patient diagnostics.
  • Diaglobal provides free report templates and willanswer all questions regarding the evaluation.

Control for quality assurance

  • HEM QS monitoring accuracy of HB measurement
  • ERY QS monitoring accuracy of ERYmeasurement

Carrying case

  • Size: 45 x 36 x 14 cm
  • Weight: 2.8 kg

Contents: photometer, power unit, battery, 10 μL capillaries, micropipettor, cuvette rack, rubbish waste bin, accessories box, writing utensils.

 

 